The vacuum hot water boiler is equipped with industrial burners with good technical performance. It adopts advanced technology such as automatic proportional adjustment of combustion, automatic adjustment of water supply, program start and stop, automatic operation, etc., and has automatic protection functions such as high and low water level alarm and extremely low water level and extinguishing. The boiler has the characteristics of compact structure, safety, simple operation, rapid installation, less pollution, low noise and high efficiency.
Energy saving vacuum hot water boiler
The vacuum hot water boiler uses the low boiling point of water at low pressure to quickly heat the heat medium water filled in the sealed furnace body, so that the heat medium water boils and evaporates high temperature water steam, and the water steam condenses on the heat exchange tube to heat the cold water in the heat exchange tube to achieve the purpose of supplying hot water.
The vacuum hot water boiler is equipped with industrial burners with good technical performance. It adopts advanced technology such as automatic proportional adjustment of combustion, automatic adjustment of water supply, program start and stop, automatic operation, etc., and has automatic protection functions such as high and low water level alarm and extremely low water level and extinguishing. The boiler has the characteristics of compact structure, safety, simple operation, rapid installation, less pollution, low noise and high efficiency.
Vacuum boiler heat conversion schematic:
Oil (natural gas)→ combustion → heat medium water → steam condensation after boiling heat transfer (vaporization → condensation → vaporization)→ heat exchanger → heat conduction → water
Low nitrogen vacuum hot water boiler has the characteristics of compact structure, safety, easy operation, rapid installation, less pollution, low noise, high efficiency, widely used in enterprises, hotels, hospitals, office buildings, civil buildings and other facilities for domestic hot water and heating.
Product parameter
item | ZKS0.35 | ZKS0.5 | ZKS0.7 | ZKS1.05 | ZKS1.4 | ZKS1.75 | ZKS2.1 | ZKS2.8 | ZKS3.5 | ZKS4.2 | |
-85/60-q | |||||||||||
Rated power | MW | 0.35 | 0.5 | 0.7 | 1.05 | 1.4 | 1.75 | 2.1 | 2.8 | 3.5 | 4.2 |
Rated working pressure | MPa | -0.02 | |||||||||
Working pressure of heat exchanger | MPa | ≤2.5 | |||||||||
Rated effluent temperature | ℃ | 85 | |||||||||
Rated return water temperature | ℃ | 60 | |||||||||
Thermal efficiency | % | ≥96 | |||||||||
Water capacity | L | 1340 | 2000 | 2600 | 3250 | 3950 | 4920 | 5950 | 7430 | 8520 | 9560 |
Inlet and outlet | DN | 50 | 65 | 80 | 100 | 100 | 125 | 125 | 150 | 150 | 200 |
blowdown | DN | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 |
Light oil | Kg/h | 32.4 | 43.2 | 64.7 | 97.1 | 129.5 | 162 | 194.2 | 259 | 324 | 389 |
Natural gas | Nlm³/h | 36.8 | 49 | 73.5 | 110.3 | 147 | 183.6 | 220.6 | 294.1 | 368 | 441.2 |
City gas | Nlm³/h | 83.4 | 111.1 | 166.7 | 250 | 333.3 | 416.7 | 500 | 666.7 | 833 | 1000 |
long | mm | 3050 | 3300 | 3550 | 4100 | 4200 | 4500 | 4600 | 5100 | 5500 | 6100 |
wide | mm | 1400 | 1400 | 1500 | 1600 | 1700 | 1800 | 2000 | 2150 | 2450 | 2400 |
high | mm | 1800 | 1800 | 1850 | 2000 | 2100 | 2200 | 2450 | 2650 | 2820 | 2820 |
weight | Kg | 2400 | 2550 | 3350 | 4600 | 5950 | 6700 | 7900 | 10500 | 14000 | 15500 |
Performance characteristics
(1) The vacuum water heater is always under negative pressure (normal working temperature is lower than 90 ° C, vacuum degree is lower than -30KPa), and there is no danger of expansion, explosion and rupture.
(2) A multi-purpose machine, a boiler can be designed with multiple heat exchangers, can provide heating, domestic hot water, swimming pool heating and so on.
(3) Safe and reliable, can be placed in the basement and the roof, the relevant state departments are not restricted, no approval procedures.
(4) no scaling, corrosion (heat exchanger stainless steel design) and other phenomena, the design service life is more than 20 years.
(5) The integrated design of boiler and heat exchanger saves space and greatly reduces the floor area.
(6) Automatic control system, high degree of automation, no need for special duty.
(7) Imported burner, efficient combustion, very low noise, exhaust gas emissions.
(8) High efficiency and energy saving, low operating cost, thermal efficiency up to 96%.
(9) Mainly used for civilian use, such as hotels, residences, office buildings, bath centers, schools, shopping malls, etc.